The recent release of MCP IC MCP-048.1A.42 [48.189.042] (48.189.8630) in July 2002 causes a major problem with Metalogic software. When the Magus library initialises it instantly enters a tight processor loop. The only option is to DS the Magus library, therefore no Metalogic software will be able to run. At this time, this MCP change is not believed to have been retrofitted to earlier MCP levels such as 46.1 and 47.1. A detour has been applied to the Magus library and is described below:
You can determine the version of the MAGUS library:
Supervisor: 'TT WS' command
Flex Inquiry: 'WHAT' command
Jampack only: PD or LFIL of the SL-ed *METALOGIC/MAGUS code file
If you intend to migrate to this MCP or later and you are not using MAGUS version 480.11 or later, please request a new support release via by email at support@metalogic.eu.com